WB-35
Features 1.Low price and high reliablity.
2.105 degrees output capacitor.
3.AC input power suitable for the world.
4.High efficiency and low operation temperature.
5.Soft-start current can reduce the AC input impact effecticly.
6.With short-circuit and overload protection.
7.100% full-load burn-in test.
8.Installed with EMI filter,minimum wave.
 
 Model S-25-5 S-25-12 S-25-15 S-25-24
 DC output voltage 5V 12V 15V 24V
 Output ovltage range(Note:2) ±2% ±1% ±1% ±1%
  Rated output current 5A 2.1A 1.7A 1.1A
Output current range 0-5A 0-2.1A 0-1.7A 0-1.1A
 Wave and noise(Note:3) 50mVp-p 100mVp-p 100mVp-p 100mVp-p
 Intel stability(Note:4) ±0.5% ±0.5% ±0.5% ±0.5%
 Load stability(Note:5) ±1% ±0.5% ±0.5% ±0.5%
 DC Output power 25W 25.2W 25.5W 26.4W
 Efficiency 65% 76% 77% 80%
 Adjustable range for DC voltage +10%,-5% ±10% ±10% ±10%
 AC input voltage range 85-132VAC/170-264VAC selected by switch 47-63Hz;240-370VDC
 Input current 0.6A/115V 0.35A/230V
 AC inrush current Cole-start current 15A/115V 30A/230V
 Leakage current <0.75mA/240VAC
 Over load protection 105%-150%  Type:pulsing hiccup shutdown Reset:auto recovery
 Over-voltage protection 115%-135%
High-temperature protection ............
Temperature coefficient ±0.03%/℃(0-50℃)
 Setup,rise,hold up time 200ms,100ms,30ms
 Vibration 10-500Hz,2G 10min,/1cycle,period for 60min,each axes 
 Withstand voltage

Input and output internal:1.5KvAC  Input and enclosure:1.5KvAC  Output and enclosure:0.5KvAC

Isolation resistance Input and output internal,Input and enclosure,Output and enclosure:500VDC/100MΩ
 Working temperature and humidity -10℃-+60℃ Refer to output derating curve 20%-90%RH
 Stoerall dimension -20℃-+85℃,10%-95%RH
 Overall dimension 99×97×35mm
 Weight 0.37kgs
 Safety standards Meet UL 1012 requirement (Not apply for the mark)
 EMC standards Meet FCC PART 15J Conduction class B
 Note: 1.The testing condition for the paramenter above is:230VAC input,rated load,25 degrees 70%RH,Temperature.
2.Error:Include the setting error,line stability and load stability.(Note:5)
3.Wave test:adoping A12 doubl wire for 20MHz,nd 0.1UF&47UF capacitor short-circuit for interrupting.
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
5.Load stavility test:The load is from 0% to 100%.