- SBW Series Three Phases Voltage Regulator/Stabilizer
- SBW-F Three Phase Separately Adjustment Voltage Regulator/ Stabilizer
- SJW Series Non-contact Computer Voltage Regulator/Stabilizer
- TND Series Servo Type Voltage Regulator/Stabilizer
- TNS Series Servo Type Voltage Regulator/Stabilizer
- JJW Series High Precision Purified Voltage Regulator/Stabilizer
- JSW Series High Precision Purified Voltage Regulator/Stabilizer
- AVR/SVR Series AC Voltage Regulator/Stabilizer
- TSD Series Wall-mounted Automatic Voltage Regulator/Stabilizer
- TM Series Relay-type Automatic Voltage Regulator/Stabilizer
- DC Stabilized Power
- Switching Power Supply
- Electric Rotary Converter
- Transformer
- UPS
- Other
Tel:0086-13736305538(Ms.Leah)
Skype:liya_sun627
Add:No.168 Lingyun Road Dongfeng Industry Zone Liushi Town Yueqing City.
Following the popularity of computer networks and the continual upgrades of information processing technology, there is now virtually no limits for network information transmissions. Undoubtedly, the server is the soul of a computer network which processes numerous network data day in and day out and is naturally more demanding in terms of power requirements computers in general. Any increase of power network load, excessively low voltage, unstable frequency or even a sudden power-off can interrupt normal network operations!
In line with the power requirements for network system, WARD has developed a new generation of on-line intelligent UPS, tieds UPS, UPS battery backup---GOLD Series 1K, 2K, 3K UPS. Its uses the Motorola microprocessor with robust processing power which is capable of detecting and controlling quickly and accurately all movements of the UPS to ensure high product reliability. In addition to providing the network with power protection for virtually zero interruption, regulated voltage and regulated frequency, interference-resistant capability and filtering of noisy signals, under normal conditions, utility power obtains via AC-DC circuit the DC bus voltage which is then converted to 220V AC output via the inverter, so as to safeguard the data over the entire network. Therefore, the power used by the load is the purified sine wave power via regulated voltage and regulated frequency with noisy signals filtered. Furthermore, WARD GOLD Series 1K, 2K, 3K UPS, tieds UPS, UPS battery backup are connected through the RS232 communication port to WARD Power Management software for power detection and power monitoring, to integrate UPS and the network server into one entity with power status available at any time. Moreover, it achieves the intelligent functions such as timer-controlled self-inspection, automatic disk-saving, automatic timer-controlled power-on and power-off and record of power status etc., to achieve the zero distance of communication between the user and UPS. Whenever utility power supply is interrupted, the UPS, tieds UPS, UPS battery backup will inform the server immediately and gets ready for switching off the unit and saving automatically all data before performing the normal power-off instruction. Even in an unattended network environment, the UPS can still ensure data safety of the network system.
Servers, Data-Center Critical network devices, Sensitive electronic equipment, Telecom...
. True on-line double conversion technology with advanced microprocessor control
. Wide input voltage range
. Zero transfer time
. Protection against all type of power problems
. Self test while start of the UPS
. Site wiring fault warning
. On-battery power-on function
. Smart RS232 communication interface
. Intelligent slot available
. Sealed lead-acid, maintenance free battery
tieds UPS, UPS battery backup
Product Series | GOLD | |||
Model | G1K | G2K | G3K | |
Rated Power | VA/W | 1kVA / 0.7kW | 2kVA / 1.4kW | 3kVA / 2.1kW |
Input | Nominal Voltage | 220VAC | ||
Voltage Range | 115 ~ 300VAC | |||
Frequency Range | 46~54Hz(default), user adjustable within 40~60Hz | |||
Power Factor | 0.97 | |||
Connection | IEC320-10A inlet | IEC320-16A inlet | ||
Output | Voltage | 220VAC ± 2% | ||
Frequency | 46~54Hz or 50Hz ± 0.2Hz (Line mode) 50Hz ± 0.2Hz ( Battery mode) | |||
Waveform | Sine Wave | |||
Distortion | 3% | 4% | ||
Overload Capability | 108%~150% for 30 sec., ³150% for 300 ms | |||
Current Crest Ratio | 3:1 | |||
Connections | IEC320 * 4 | IEC320 * 6 | IEC320 * 3 and Terminal Block | |
Battery | Type | Sealed, Maintenance free, Lead-Acid (Panasonic) | ||
Quantity | 3 pieces | 8 pieces | ||
Back-up Time (Full load) | 5 min | 9 min | 5 min | |
Recharge Time | 5 hrs to 90% of capacity after full load discharge | |||
Bypass | Automatic Transfer | on overload and UPS failure | ||
Before UPS Power-on | Default “NO”, user adjustable to “YES” | |||
Voltage Range | 80~264VAC (Default), user adjustable within 80~286VAC | |||
Transfer Time | 0 ms; less than 4 ms from inverter to bypass and vice versa | |||
LED Indicators | Status | Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault | ||
Bypass, On battery mode, Battery low, Overload, Fault | ||||
Acoustic Noise | At 1 meter distance | 45 dBA | 50 dBA | |
Communications | DB-9 Port | RS-232 Serial Interface | ||
Intelligent Slot | Options: WebPower, AS400 Card or WinPower CMC | |||
Network Surge Protection | RJ45 I/O port available for network or Fax/Modem | |||
Environmental | Operating Temperature | 0 ~ 40°C | ||
Operating Humidity | 20 ~ 90% non-condensing | |||
Weight | Net (Kg) | 13 | 31.5 | 32 |